Part C2 Fire resistance and stability
SA C2D2 Type of construction required2019: C1.1
- certain Class 2, 3 or 9c buildings, in C2D6; and
- a Class 4 part of a building located on the top storey, in C2D4(2); and
- open spectator stands and indoor sports stadiums, in C2D8; and
- Class 2 buildings located within 3 m of a brush fence and Class 10b brush fences located within 3 m of a Class 2 building, in SA C2D2(3) and (4); and
- a Class 7b bulk grain storage facility in SA C2D16.
SA C2D2 Type of construction required2019: C1.1
SA C2D2 Type of construction required2019: C1.1
SA C2D16 Class 7b bulk grain storage facilities2019: SA C1.15
The external walls of a bulk grain storage facility need not be of fire-resisting construction if—
- The external walls are 3 m or more from an allotment boundary and more than 6 m from any other building on the same allotment, other than a Class 10 building; and
- a fire separation space of not less than 2 m is provided between cell type silos; and
- the external walls are—
- of non-combustible construction; or
- of Type C construction.