Part F4 Sanitary and other facilities
NSW F4P6 Microbial control for water systems
This clause been deliberately left blank
F4P6 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2012, under the Public Health Act 2010.
User group | Facility type | Design occupancy | Number |
---|---|---|---|
Male patrons | Closet pans | 1 - 100 | 1 |
101 - 300 | 2 | ||
>300 | Add 1 per 200 | ||
Urinals | 1 - 50 | 1 | |
51 - 100 | 2 | ||
101 - 150 | 3 | ||
151 - 200 | 4 | ||
201 - 250 | 5 | ||
>250 | Add 1 per 100 | ||
Washbasins | 1 - 50 | 1 | |
51 - 200 | 2 | ||
>200 | Add 1 per 200 | ||
Female patrons | Closet pans | 1 - 25 | 1 |
26 - 50 | 2 | ||
51 - 100 | 3 | ||
101 - 150 | 4 | ||
151 - 200 | 5 | ||
201 - 250 | 6 | ||
>250 | Add 1 per 100 | ||
Washbasins | 1 - 50 | 1 | |
51 - 150 | 2 | ||
>150 | Add 1 per 200 |
Table Notes
Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.
Delete table (F4D4d) and insert NSW table (F4D4d) as follows:
User group | Facility type | Design occupancy | Number |
---|---|---|---|
Male patrons | Closet pans | 1 - 100 | 1 |
101 - 300 | 2 | ||
>300 | Add 1 per 200 | ||
Urinals | 1 - 50 | 1 | |
51 - 100 | 2 | ||
101 - 150 | 3 | ||
151 - 200 | 4 | ||
201 - 250 | 5 | ||
>250 | Add 1 per 100 | ||
Washbasins | 1 - 50 | 1 | |
51 - 200 | 2 | ||
>200 | Add 1 per 200 | ||
Female patrons | Closet pans | 1 - 25 | 1 |
26 - 50 | 2 | ||
51 - 100 | 3 | ||
101 - 150 | 4 | ||
151 - 200 | 5 | ||
201 - 250 | 6 | ||
>250 | Add 1 per 100 | ||
Washbasins | 1 - 50 | 1 | |
51 - 150 | 2 | ||
>150 | Add 1 per 200 |
Note
- Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.
- Sanitary facilities need not be provided for patrons in a small live music or arts venue that is not a licensed premises.
NSW F4D10 Microbial (legionella) control
This clause been deliberately left blank
F4D10 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2012, under the Public Health Act 2010.