NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings

I1

Part I1 Class 9b buildings

Part I1 Class 9b buildings

NSW I1D1 Application of Part2019: NSW H1.1

Delete clause I1D1 and insert NSW I1D1 as follows:

(1) For a Class 9b building or part of a building that is not an entertainment venue

  1. the Deemed-to-Satisfy Provisions of Part I1 apply to every enclosed Class 9b building or part of a building which—
    1. is a school assembly, church or community hall with a stage and any backstage area with a total floor area of more than 300 m2; or
    2. otherwise, has a stage and any backstage area with a total floor area of more than 200 m2; or
    3. has a stage with an associated rigging loft; and
  2. notwithstanding (1)(a)—
    1. I1D4 applies to every open or enclosed Class 9b building; and
    2. I1D7 applies to every enclosed Class 9b building.

(2) For a Class 9b building that is an entertainment venue, NSW Part I4 applies in replacement of Part I1.