NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

G9

SA Part G9 Miscellaneous provisions

SA Part G9 Miscellaneous provisions

Introduction to this Part

This Part sets out miscellaneous addition requirements.

Performance Requirements

NCC Blurbs

An attachment to a building must incorporate features that will—

  1. protect it against corrosion; and
  2. collect and discharge water run-off safely; and
  3. prevent its projection affecting adjacent road safety conditions or pedestrian traffic; and
  4. provide resistance to the spread of fire if it overhangs a street boundary,

to the degree necessary to avoid creating hazardous conditions that may cause injury to people passing below or driving past.

NCC Title

Attachments to buildings

NCC State
SA
NCC SPTC Current
Attachments to buildings

Deemed-to-Satisfy Provisions

NCC Blurbs

Performance RequirementSA G9P1 is satisfied by complying with SA G9D2 and SA G9D3.

NCC Title

Deemed-to-Satisfy Provisions

NCC State
SA
NCC SPTC Current
Deemed-to-Satisfy Provisions
NCC Blurbs

SA G9D3 applies to Class 2 to 9 buildings.

NCC Title

Application of Part

NCC State
SA
NCC SPTC Current
Application of Part
NCC Blurbs

(1) An attachment to a building that is in the nature of a balcony or awning, bridge, gangway, hoarding or trade sign, sky sign, mast, flagpole, tower, aerial or antenna, lantern, cathead, crane, chimney, flue or duct, or an installation for cleaning and maintenance must—

  1. have all metal parts of corrosion resistant metal, or other metal suitably protected; and
  2. not overhang any street boundary at a height less than 2.5 m above the footpath, or 4 m above the roadway; and
  3. be provided with drainage to prevent rainwater or condensate falling onto or running across the footpath, unless either it is a retractable awning in the nature of a sun blind, or unless the total catchment area for run-off is less than 1.5 m2.

(2) A balcony or awning that overhangs a street boundary—

  1. must not extend closer than 450 mm to the kerb of the roadway; and
  2. must be constructed of non-combustible or fire-retardant materials throughout, except that timber battens may be used to support the soffit lining.
NCC Title

Attachments to buildings

NCC State
SA
NCC SPTC Current
Attachments to buildings