Filter
Section G Ancillary Provisions
Part G1 Minor Structures and Components
PERFORMANCE REQUIREMENTS
Vic GP1.2
A barrier must be provided to a swimming pool and must—
be continuous for the full extent of the hazard; and
be of a strength and rigidity to withstand the foreseeable impact of people; and
restrict the access of young children to the pool and the immediate pool surrounds; and
have any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.
Application
Vic GP1.2(a) only applies to a swimming pool with a depth of water more than 300 mm associated with—
- a Class 2 or 3 building or Class 4 part of a building; or
- a children's service.
Delete G1.1(a) and Insert Vic G1.1(a) as follows:
DEEMED-TO-SATISFY PROVISIONS
Vic G1.1 Swimming pools
A swimming pool associated with a children's service, with a depth of water more than 300 mm, must have fencing or other barriers in accordance with AS 1926 Parts 1 and 2.