NCC 2016 Volume Two
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c
Part 3.3.2 Reinforced Masonry

Part 3.3.2 Reinforced Masonry

Appropriate Performance Requirements

Appropriate Performance Requirements

Where an alternative reinforced masonry system is proposed as a Performance Solution to that described in Part 3.3.2, that proposal must comply with—

  1. ; and
  2. the relevant Performance Requirements determined in accordance with 1.0.7.

3.3.2.0

P2.1.1 is satisfied for reinforced masonry if it is designed and constructed in accordance with one of the following:

(a)

AS 3700.

(b)

AS 4773 Parts 1 and 2.

Explanatory information

Explanatory information:

Design requirements for other materials that may be used in combination with masonry (heavy steel support beams etc.) are described in Part 3.11 — Structural design.