NCC 2016 Volume Two
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c
ACT 6 — Swimming Pool Construction

ACT 6 — Swimming Pool Construction

ACT 6.1 Swimming Pool Construction

Application

Application:

This requirement is to be applied in conjunction with Part 3.9.3.

ACT 6.1 SWIMMING POOL CONSTRUCTION

Indoor or outdoor permanent bathing, wading and swimming pools must—

(a)

where the capacity of the pool exceeds 10 m3

(i)

be of the recirculation type in which the water circulation is maintained through the pool by pumps, the water drawn from the pool being clarified and disinfected before being returned to the pool; and

(ii)

have means of egress provided in the form of ladders, steps in the floor of the pool or a ramp; and

(b)

be capable of being completely emptied and any discharge or overflow and pool backwash filter must be connected to the sewer drainage system.