NCC 2016 Volume Two
Search the National Construction Code editions
NSW Part 3.12.3 Building Sealing
Appropriate Performance Requirements
Where a Performance Solution to NSW 3.12.3 is proposed, that proposal must comply with—
Compliance with NSW 3.12.3.1 satisfies NSW P2.6.1(b) for building sealing.
is not applicable to—
existing buildings being relocated; or
Class 10a buildings—
without a conditioned space; or
for the accommodation of vehicles; or
parts of buildings that cannot be fully enclosed; or
a permanent building opening, in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; or
a building in climate zones 2 and 5 where the only means of air-conditioning is by using an evaporative cooler.
The sealing of a building must comply with the national BCA provisions to 3.12.3.6.
Explanatory Information:
Such rooms are unlikely to be conditioned given the high air flow rates; therefore applications of the Performance Requirement to these parts of buildings would not result in reduction in energy use.