/editions/2016/ncc-2016-volume-one/new-south-wales/section-d-access-and-egress
Part D1 Provision for Escape
Add D1.2(d)(vii) as follows:
NSW D1.2 Number of exits required
(d)
(vii)
any storey or mezzanine within an auditorium in an entertainment venue.
Insert NSW D1.6(f)(vi), and (j) as follows:
NSW D1.6…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/part-c1-fire-resistance-and-stability
C1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1
to C1.13, C2.1 to C2.14 and C3.1toC3.17; and
(ii)
in a building containing an…
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/part-c1-fire-resistance-and
C1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1
to C1.14, C2.1 to C2.14 and C3.1toC3.17; and
(ii)
in a building containing an…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/specification-c11-fire
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/specification-c11-fire-resisting
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/part-c1-fire-resistance
Deemed-to-Satisfy Provisions
C1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17;…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/part-c1-fire-resistance-and-stability
Deemed-to-Satisfy Provisions
C1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17;…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/specification-c11-fire-resisting
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/specification-c11-fire-resisting
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
3.12.2.1 External glazing
(a)
The aggregate conductance of the glazing in each storey, including any…
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
3.12.2.1 External glazing
(a)
The aggregate conductance of the glazing in each storey, including any…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jvb
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jvb-modelling
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3122-external
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
Energy Efficiency NCC Volume Two
3.12.2.1 External glazing
(a)
The aggregate conductance…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
Energy Efficiency NCC Volume Two
3.12.2.1 External glazing
(a)
The aggregate conductance…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-39-safe-movement-and-access/part-392-barriers
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative barrier is proposed as a Performance Solution to that described in Part 3.9.2, that proposal must comply with—
Performance…
/editions/2019/ncc-2019-volume-two/part-39-safe-movement-and-access/part-392-barriers-and-handrails
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative barrier is proposed as a Performance Solution to that described in Part 3.9.2, that proposal must comply with—
Performance…