/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-37-fire-safety/part-371-fire-properties
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative fire property for materials and construction is proposed as a Performance Solution to that described in Part 3.7.1, that proposal must…
/editions/2019/ncc-2019-volume-two/part-37-fire-safety/part-371-fire-properties-materials-and
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative fire property for materials and construction is proposed as a Performance Solution to that described in Part 3.7.1, that proposal must…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/part-j1-building
J1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy
Solution is proposed, Performance
RequirementJP1 is
satisfied by complying with—
(i…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/part-j1-building-fabric
J1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementJP1 is satisfied by complying with—
(i)
J0.1 to J0.5; and
(ii)
J1.1 to J1.6; and
(iii)
J3.1 to J3.7; and…
/news/2021/what-and-how-fire-hazard-properties-wall-and-ceiling-linings
You may have a report or certificate indicating satisfactory fire hazard properties for a wall or ceiling lining, but still may not be meeting the requirements of the NCC.
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/specification-j16-floor-construction
1. Scope
This Specification describes the thermal performance of some common forms of floor construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of floor construction.
2.…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/specification-j16-floor
1. Scope
This Specification describes the thermal performance of some common forms of floor construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of floor construction.
2.…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jvb
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jvb-modelling
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/specification-j12-material-properties
1. Scope
This Specification lists the thermal properties of some common construction materials.
Intent
To clarify that covers the relevant properties attributed to common construction materials, air films and airspaces, and reflective…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/specification-j12-material
1. Scope
This Specification lists the thermal properties of some common construction materials.
Intent
To clarify that covers the relevant properties attributed to common construction materials, air films and airspaces, and reflective…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-j12
1. Scope
This Specification lists the thermal properties of some common construction materials.
Intent
To clarify that Specification J1.2 covers the relevant properties attributed to common construction materials, air films and airspaces, and…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-j12-material-properties
1. Scope
This Specification lists the thermal properties of some common construction materials.
Intent
To clarify that Specification J1.2 covers the relevant properties attributed to common construction materials, air films and airspaces, and…
/editions/2016/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2016-a1/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2016/ncc-2016-volume-two/part-37-fire-safety/part-371-fire-separation
Appropriate Performance Requirements
Appropriate
Where an alternative fire separation design is proposed as a Performance Solution to that described in Part 3.7.1, that proposal must comply with—
P2.3.1
; and
the relevant Performance…
/editions/2016-a1/ncc-2016-volume-two/part-37-fire-safety/part-371-fire-separation
Appropriate Performance Requirements
Appropriate
Where an alternative fire separation design is proposed as a Performance Solution to that described in Part 3.7.1, that proposal must comply with—
P2.3.1
; and
the relevant Performance…