/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings
Design scenario in brief
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the…
/editions/2019/ncc-2019-volume-one/section-g-ancillary-provisions/part-g1-minor-structures-and-dts
G1.0 Deemed-to-Satisfy Provisions
(a)
Performance RequirementGP1.1 must be complied with.
Explanatory information
There is no Deemed-to-Satisfy Provisio n for this Performance Requirement.
Tas G1.0(b)
(b)
Where a…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/part-g1-minor-dts
G1.0 Deemed-to-Satisfy Provisions
(a)
Performance RequirementGP1.1 must be complied with.
Explanatory information
There is no Deemed-to-Satisfy Provisio n for this Performance Requirement.
Tas G1.0(b)
(b)
Where a…
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e18-fire
1. Scope
This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e18-fire-control
1. Scope
This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e18
1. Scope
This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e18-fire-control
1. Scope
This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
/editions/2019/ncc-2019-volume-two/section-2-performance-provisions/part-24-health-and-amenity
Explanatory information:
Explanatory information:
Objective
O2.4.1 Wet areas
The Objective is to safeguard the occupants from illness or injury and protect the building from damage caused by the accumulation of internal moisture…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/section-2-performance-provisions/part-24-health
Explanatory information:
Explanatory information:
Objective
O2.4.1 Wet areas
The Objective is to safeguard the occupants from illness or injury and protect the…
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements
Appropriate :
Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with—
P2.2.1
; and
the relevant Performance…
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/14-design-scenarios
1.4 Design scenarios: NCC Performance Requirements
This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance…
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/14-design-scenarios
This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance Requirements set out in Table 1.1.
The design…
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/14-design-scenarios
1.4 Design scenarios: NCC Performance Requirements
This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/14
1.4 Design scenarios: NCC Performance Requirements
This Verification Method
presents specific design
scenarios that must be considered in order to demonstrate that the fire safety aspects of a building
design…