/ncbp/suspect-non-conformance
If you think a product or material may be non-conforming you can contact the relevant authorities by visiting the Jurisdictional contacts page and select your state or territory.
/news/2020/demonstrating-ncc-compliance-using-5113
AS 5113:2016 Classification of external walls of buildings based on reaction to fire performance (AS 5113) is a standard that sets out procedures and criteria for classifying external walls of buildings.
Schedule of Products - Fittings – Plastic
/schedule-products-fittings-plastic
Schedule of Products - Fittings – Plastic
/news/2022/improved-condensation-management-ncc-2022
NCC 2022 builds on the NCC 2019 provisions to further decrease health risks associated with condensation in new homes.
/news/2020/allowable-encroachments-how-close-too-close
Did you know that NCC Volume Two contains requirements relevant to plumbers, gas-fitters and air-conditioning installers?
/editions/2019/ncc-2019-volume-one/tasmania/schedule-4-referenced-documents
Tas Schedule 4 Referenced documents
All legislation referenced in this Appendix is Tasmanian State legislation unless noted otherwise.
All referenced documents including legislation, codes, Australian Standards, guidelines and codes of practice are…
/editions/2019/ncc-2019-volume-one/western-australia/section-h-special-use-buildings
Insert WA Part H101 as follows:
/editions/2019-a1/ncc-2019-volume-one-amendment-1/western-australia/section-h-special-use-buildings
Insert WA Part H101 as follows:
/editions/2019/ncc-2019-volume-two/part-38-health-and-amenity/part-387-condensation-management
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative condensation management system is proposed as a Performance Solution to that described in Part 3.8.7, that proposal must comply with—…
/editions/2016/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/editions/2016-a1/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
/news/2021/introducing-your-abcb-industry-board-members
The Australian Building Codes Board is made up of eighteen members including a Chair, the head of each state and territory building administration, a Commonwealth building policy representative, up to seven industry representatives, and a…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/news/2023/livable-housing-design-webinar-questions-and-answers
In March 2023, we delivered a series of webinars for practitioners to learn about key changes and new provisions in NCC 2022 Volume One and Volume Two for energy efficiency, condensation management and livable housing design.
/ncc-navigator/thermal-bridging-commercial-buildings
This NCC Navigator provides an introduction to thermal bridging and how the NCC addresses it for commercial buildings in NCC Volume One. It explains how to account for thermal bridges when calculating the Total R-Value of certain construction types.…
/resource/case-study/calculating-total-r-value-case-study-2
This case study shows how to calculate the Total R-Value, including thermal bridging, for a wall system in a Class 6 shop located in climate zone 3. The wall component consists of solid concrete on a steel framed wall.