2.7 Design scenario (IS)
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings Design scenario in brief Interior surfaces are exposed to a growing fire that potentially endangers building occupants. Required outcome Demonstrate that the level of safety be at least…
2.7 Design scenario (IS)
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings Design scenario in brief Design scenario in brief Interior surfaces are exposed to a growing fire that potentially endangers building occupants. Required outcome Demonstrate that the…
2.7 Design scenario (IS)
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings Design scenario in brief Interior surfaces are exposed to a growing fire that potentially endangers building occupants. Required outcome Demonstrate that the level of safety be at least…
2.7 Design scenario (IS)
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings Design scenario in brief Interior surfaces are exposed to a growing fire that potentially endangers building occupants. Required outcome Demonstrate that the level of safety be at least…
2.7 Design scenario (IS)
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings Design scenario in brief Design scenario in brief Interior surfaces are exposed to a growing fire that potentially endangers building occupants. Required outcome Demonstrate that the…
Part G1 Minor structures and components (DtS)
/editions/2019/ncc-2019-volume-one/section-g-ancillary-provisions/part-g1-minor-structures-and-dts
G1.0 Deemed-to-Satisfy Provisions (a) Performance RequirementGP1.1 must be complied with. Explanatory information There is no Deemed-to-Satisfy Provisio n for this Performance Requirement. Tas G1.0(b) (b) Where a…
Part G1 Minor structures and components (DtS)
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/part-g1-minor-dts
G1.0 Deemed-to-Satisfy Provisions (a) Performance RequirementGP1.1 must be complied with. Explanatory information There is no Deemed-to-Satisfy Provisio n for this Performance Requirement. Tas G1.0(b) (b) Where a…
List of Amendments - NCC 2016 - Volume One
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One. The notes provide a description of…
Specification E1.8 Fire Control Centres
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e18-fire-control
1. Scope This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
Specification E1.8 Fire Control Centres
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e18-fire
1. Scope This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
Specification E1.8 Fire control centres
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e18
1. Scope This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
Specification E1.8 Fire control centres
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e18-fire-control
1. Scope This Specification describes the construction and content of required fire control centres and rooms. A fire control room is a fire control centre in a dedicated room with additional specific requirements. Clauses 2 to 5 apply to fire…
Part 2.4 Health and amenity
/editions/2019/ncc-2019-volume-two/section-2-performance-provisions/part-24-health-and-amenity
Explanatory information: Explanatory information: Objective O2.4.1 Wet areas The Objective is to safeguard the occupants from illness or injury and protect the building from damage caused by the accumulation of internal moisture…
Part 2.4 Health and amenity
/editions/2019-a1/ncc-2019-volume-two-amendment-1/section-2-performance-provisions/part-24-health
Explanatory information: Explanatory information: Objective O2.4.1 Wet areas The Objective is to safeguard the occupants from illness or injury and protect the…
Part 3.5.2 Gutters And Downpipes
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements Appropriate : Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with— P2.2.1 ; and the relevant Performance…
Part 3.5.2 Gutters And Downpipes
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-352-gutters-and-downpipes
Appropriate Performance Requirements Appropriate : Where an alternative gutter and downpipe system is proposed as a Performance Solution to that described in Part 3.5.2, that proposal must comply with— P2.2.1 ; and the relevant Performance…
1.4 Design scenarios: NCC Performance Requirements
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/14-design-scenarios
1.4 Design scenarios: NCC Performance Requirements This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance…
1.4 Design scenarios: NCC Performance Requirements
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/14-design-scenarios
This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance Requirements set out in Table 1.1. The design…
1.4 Design scenarios: NCC Performance Requirements
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/14-design-scenarios
1.4 Design scenarios: NCC Performance Requirements This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design comply with the fire safety Performance…
1.4 Design scenarios: NCC Performance Requirements
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/14
1.4 Design scenarios: NCC Performance Requirements This Verification Method presents specific design scenarios that must be considered in order to demonstrate that the fire safety aspects of a building design…

Pagination

  • First page « First
  • Previous page ‹ Previous
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • …
  • Next page Next ›
  • Last page Last »

Areas of Interest

  • Plumbing and drainage (11)
  • Fire safety (10)
  • Performance (9)
  • Structural safety (9)
  • Building services (7)
  • Health and amenity (6)
  • NCC compliance (6)
  • Access and egress (5)
  • Energy efficiency (5)
  • Product certification (4)
  • Water services (4)

Content type

  • Show all (681)
  • NCC Page (560)
  • Article (52)
  • Page (28)
  • Resource (26)
  • NCC Navigator Page (6)
  • Video (3)
  • (-) PCD (6)

Domain

File type

Get the latest news and articles from the ABCB delivered straight to you. Subscribe to ABCB communications here

In the spirit of reconciliation the Australian Building Codes Board acknowledges the Traditional Custodians of country throughout Australia and their connections to land, sea and community. We pay our respect to their elders past and present and extend that respect to all Aboriginal and Torres Strait Islander peoples today.

Home

Info

  • Copyright
  • Privacy
  • Disclaimer
  • Accessibility
  • Help & Support

Find us on:

  • Facebook
  • LinkedIn
  • Youtube