/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/part-j3-building-sealing
J3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsJP1 and JP3 are satisfied by complying with—
(i)
J0.1
to J0.3; and
(ii)
J1.1
to J1.6; and
(iii)
J2.1
to J2.5; and…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/part-j3-building-sealing
J3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsJP1 and JP3 are satisfied by complying with—
(i)
J0.1
to J0.3; and
(ii)
J1.1
to J1.6; and
(iii)
J2.1
to J2.5; and…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/part-j3-building
J3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementJP1 is satisfied by complying with—
(i)
J0.1 to J0.5; and
(ii)
J1.1 to J1.6; and
(iii)
J3.1 to J3.7; and…
/resource/calculator/ncc-2022-volume-two-gutters-downpipes-and-overflow-gdo-calculator
Assists in developing a better understanding of the NCC Volume Two ABCB Housing Provision Standard Gutters and Downpipes provisions.
To use the GDO Calculator enter information about the location, roof design and types of overflow measures. Based…
Calculator-GDO-NCC-2022.xlsx
(542.88 KB)
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.13, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/part-c3-protection
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17; and
(ii)
in a building…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17; and
(ii)
in a building…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/section-c-fire
Performance Requirements
CP1 Structural stability during a fire
A building must have elements which will, to the degree necessary, maintain structural stability during a fire appropriate to—
(a)
the function or use of the building; and…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/section-c-fire-resistance
Performance Requirements
CP1 Structural stability during a fire
A building must have elements which will, to the degree necessary, maintain structural stability during a fire appropriate to—
(a)
the function or use of the building; and…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/specification-c113
1. Scope
This Specification sets out requirements for cavity barriers in fire-protected timber construction.
Specification C1.13
sets out requirements for cavity barriers used for fire-protected timber. A cavity barrier is a barrier/enclosure…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/specification-c113-cavity-barriers-fire
1. Scope
This Specification sets out requirements for cavity barriers in fire-protected timber construction.
Specification C1.13
sets out requirements for cavity barriers used for fire-protected timber. A cavity barrier is a barrier/enclosure…
/editions/2016-a1/ncc-2016-volume-two/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative structural steel member system is proposed as a Performance Solution to that described in Part 3.4.4, that proposal must comply with—
P2.1.1;…
/editions/2016/ncc-2016-volume-two/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative structural steel member system is proposed as a Performance Solution to that described in Part 3.4.4, that proposal must comply with—
P2.1.1;…
/news/2025/update-progress-next-edition-ncc
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e15-fire
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that gives the design and installation details for sprinkler systems required by the Deemed-to-Satisfy Provisions…
/editions/2016-a1/ncc-2016-volume-one/section-f-health-and-amenity/part-f1-damp-and-weatherproofing
VERIFICATION METHODS
FV1 Weatherproofing
(a)
Compliance with for weatherproofing of an external wall— that
(i)
has a risk score of 20 or less, when the sum of all risk factor scores are determined in accordance with Table FV1.1; and
(ii…
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e15-fire-sprinkler
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that gives the design and installation details for sprinkler systems required by the Deemed-to-Satisfy Provisions…
/editions/2016/ncc-2016-volume-one/section-f-health-and-amenity/part-f1-damp-and-weatherproofing
VERIFICATION METHODS
FV1 Weatherproofing
(a)
Compliance with for weatherproofing of an external wall— that
(i)
has a risk score of 20 or less, when the sum of all risk factor scores are determined in accordance with Table FV1.1; and
(ii…
Temporary structures
/resource/standard/temporary-structures
This Standard provides technical design criteria requirements for temporary structures, covering structural safety (particularly determining appropriate wind actions), fire safety (including fire resistance of materials; fire safety services and…
Standard-temporary-structures.pdf
(2.63 MB)