/editions/2016/ncc-2016-volume-two/south-australia/sa-5-access-people-disability
Limitation
Limitation:
SA 5 applies to Class 1 buildings in developments of 20 or more dwellings.
SA 5.1 Performance Provisions
Objective
Provide, as far as is reasonable, people with safe, equitable and dignified access to a…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-j15a-calculation-u
1. Scope
This specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction.
Intent
This Specification describes the two calculation methods for determining if wall-glazing construction complies…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-j15a
1. Scope
This specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction.
Intent
This Specification describes the two calculation…
/editions/2016/ncc-2016-volume-one/victoria/section-e-services-and-equipment
Part E1 Fire Fighting Equipment
Add references to shared accommodation building and residential care building in Table E1.5 and substitute Note 4 of Table E1.5 as follows:
VIC Table E1.5 REQUIREMENTS FOR SPRINKLERS
Occupancy
When…
/editions/2016-a1/ncc-2016-volume-one/victoria/section-e-services-and-equipment
Part E1 Fire Fighting Equipment
Add references to shared accommodation building and residential care building in Table E1.5 and substitute Note 4 of Table E1.5 as follows:
VIC Table E1.5 REQUIREMENTS FOR SPRINKLERS
Occupancy
When…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/history-pca-adoption/history-adoption
1.0 Adoption of PCA 2011
The 2011 edition of the PCA was adopted by the Commonwealth, States and Territories as set out in Table 1.0.
Table 1.0 History of adoption of PCA 2011…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/part-j1-building-fabric
J1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements and are satisfied by complying with—
(i)
J0.1
to J0.3; and
(ii)
J1.1
to J1.6; and
(iii)
J2.1
to J2.5; and
(iv)…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/part-j1-building-fabric
J1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements and are satisfied by complying with—
(i)
J0.1
to J0.3; and
(ii)
J1.1
to J1.6; and
(iii)
J2.1
to J2.5; and
(iv)…
/editions/2016/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
/editions/2016-a1/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
/initiatives/prefabricated-modular-and-offsite-construction
Building Ministers have asked the Australian Building Codes Board (ABCB) to work with industry and governments to develop guidance that facilitates the increased use of prefabricated and modular construction technologies in Australia that are compliant…
/editions/2016/ncc-2016-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm maximum…
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/section-c-fire-resistance
VERIFICATION METHODS
CV1
Compliance with CP2(a)(iii) to avoid the spread of fire between buildings on adjoining allotments is verified when it is calculated that—
(a)
a building will not cause heat flux in excess of those set out in column 2 of…
/editions/2016-a1/ncc-2016-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm maximum…
/editions/2019/ncc-2019-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-32-footings-and-slabs/part-323-concrete-and
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm…
/editions/2016-a1/ncc-2016-volume-three/queensland/section-b-water-services
Part B1 Cold Water Services
Delete B1.2(a) and (c) and insert Qld B1.2(a) and (c) as follows:
Qld B1.2 General requirements
(a)
The design, construction, installation, replacement, repair, alteration and maintenance of cold water services…
/editions/2016/ncc-2016-volume-three/queensland/section-b-water-services
Part B1 Cold Water Services
Delete B1.2(a) and (c) and insert Qld B1.2(a) and (c) as follows:
Qld B1.2 General requirements
(a)
The design, construction, installation, replacement, repair, alteration and maintenance of cold water services…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/specification-f52
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of
construction.
(b)
Wall systems listed in…