/news/2023/use-15621-demonstrating-weatherproofing-compliance-metal-wall-cladding-panel-systems
Does F3D5(c), by reference to AS 1562.1, preclude the use of panel-style metal wall cladding that does not meet this standard? The short answer is ‘no’. In those circumstances there is another method of demonstrating NCC compliance.
/editions/ncc-2022/adopted/volume-one/c-fire-resistance/11-smoke-proof-walls-health-care-and-residential-care-buildings
S11C1
Scope
2019: Spec C2.5: 1…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/specification-c25-smoke-proof-walls
1. Scope
This Specification sets out requirements for the construction of smoke-proof walls in Class 9a health-care buildings and Class 9c buildings. Smoke proof walls required to have an FRL are to be in accordance with Clause A5.4.
Intent…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/specification-c25-smoke-proof-walls
1. Scope
This Specification sets out requirements for the construction of smoke-proof walls in Class 9a health-care buildings and Class 9c buildings. Smoke proof walls required to have an FRL are to be in accordance with Clause A2.3.
Intent…
/resources/videos/do-control-joints-tilt-concrete-external-walls-require-fire-protection
This video describes how C3.1 Application of Part provides concession in Part C3 of the NCC.
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/specification-c25-smoke-proof-walls
1. Scope
This Specification sets out requirements for the construction of smoke-proof walls in Class 9a health-care buildings and Class 9c buildings. Smoke proof walls required to have an FRL are to be in accordance with Clause A2.3.
Intent…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/specification-c25-smoke
1. Scope
This Specification sets out requirements for the construction of smoke-proof walls in Class 9a health-care buildings and Class 9c buildings. Smoke proof walls required to have an FRL are to be in accordance with Clause A5.4.
Intent…
/editions/ncc-2022/adopted/housing-provisions/12-ancillary-provisions/part-123-attachment-framed-decks-and-balconies-external-walls-buildings-using
12.3.1
Application
New for 2022…
/editions/2016/ncc-2016-volume-one/appendix-australian-capital-territory/section-d-access-and-egress
Add ACT DP0.1 to ACT DP0.5 as follows:
PERFORMANCE REQUIREMENTS
ACT DP0.1 Existing passenger lift or existing toilet concession
Access to passenger lifts or toilets need not be provided in accordance with the requirements of Sections D, E or F…
/editions/2016-a1/ncc-2016-volume-one/appendix-australian-capital-territory/section-d-access-and
Add ACT DP0.1 to ACT DP0.5 as follows:
PERFORMANCE REQUIREMENTS
ACT DP0.1 Existing passenger lift or existing toilet concession
Access to passenger lifts or toilets need not be provided in accordance with the requirements of Sections D, E or F…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/tasmania/tas-part-h113-foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2 General
(a)
Every…
/editions/2019/ncc-2019-volume-one/tasmania/tas-part-h113-foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2 General
(a)
Every…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been deliberately left blank.
Note…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/news/2020/plumbing-performance-solutions-western-australia
On 1 May 2015, Western Australia (WA) adopted the Plumbing Code of Australia (PCA) as the primary technical compliance standard for plumbing work.
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/part-f6-condensation
Performance Requirements
FP6.1 Condensation and water vapour management
In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated with water vapour and condensation must be managed to minimise their impact on…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/part-f6-condensation-management
Performance Requirements
FP6.1 Condensation and water vapour management
In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated with water vapour and condensation must be managed to minimise their impact on…
PCD 2025 - Condensation mitigation
/pcd/pcd-2025-condensation-mitigation
These changes aim to better manage the risk of condensation in the residential parts of some buildings, improving people’s health outcomes and reducing building rot in modern buildings.