/editions/2016-a1/ncc-2016-volume-two/abbreviations-and-symbols/abbreviations-and-symbols
Abbreviations and Symbols used in the Housing Provisions include:
ABBREVIATIONS
ABCB
Australian Building Codes Board
AISC
Australian Institute of Steel Construction
ALGA
Australian Local Government Association
AS
Australian Standard…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/tasmania/tas-section-h-site-waste-water-systems
Tas Part H1 On-site waste water management systems
Tas Introduction to this Part
This Part sets out the requirements for the design, construction, installation, replacement repair, alteration and maintenance of any part of an on-site…
/editions/2019/ncc-2019-volume-three/tasmania/tas-section-h-site-waste-water-systems
Tas Part H1 On-site waste water management systems
Tas Introduction to this Part
This Part sets out the requirements for the design, construction, installation, replacement repair, alteration and maintenance of any part of an on-site…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-2-abbreviations-and-symbols/schedule-2
Abbreviations and symbols used in the NCC include:
Abbreviations
Abbreviation
Definition
ABCB
Australian…
/editions/2019/ncc-2019-volume-two/schedule-2-abbreviations-and-symbols/schedule-2-abbreviations-and
Abbreviations and symbols used in the NCC include:
Abbreviations
Abbreviation
Definition
ABCB
Australian Building Codes Board
AC
Alternating Current
AS
Australian Standard
ASET
Available Safe Egress Time
ASTM
American Society…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3121-building
3.12.1 Application
(a)
The provisions of 3.12.1.1 to
3.12.1.5 apply to—
(i)
a Class 1 building; and…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3121-building-fabric
3.12.1 Application
(a)
The provisions of 3.12.1.1 to 3.12.1.5 apply to—
(i)
a Class 1 building; and
(ii)
a Class 10a building with a conditioned space.
(b)
The provisions of 3.12.1.6 apply to a Class 1 building with…
Schedule of Products - Fittings – Metallic
/schedule-products-fittings-metallic
Schedule of Products - Fittings – Metallic
/editions/2016/ncc-2016-volume-one/abbreviations-and-symbols/abbreviations-and-symbols
Abbreviations and Symbols used in the BCA include:
ABBREVIATIONS
ABCB
Australian Building Codes Board
AISC
Australian Institute of Steel Construction
ALGA
Australian Local Government Association
AS
Australian Standard
ASTM
American…
/editions/2016-a1/ncc-2016-volume-one/abbreviations-and-symbols/abbreviations-and-symbols
Abbreviations and Symbols used in the BCA include:
ABBREVIATIONS
ABCB
Australian Building Codes Board
AISC
Australian Institute of Steel Construction
ALGA
Australian Local Government Association
AS
Australian Standard
ASTM
American…
/news/2020/render-render-wall-can-i-put-render-them-all
The look and feel of rendered facades is familiar throughout Australia and new technologies have given rise to various synthetic renders, but have you considered if render is ever required by the Deemed-to-Satisfy (DTS) Provisions of the NCC to be non-…
/editions/2016/ncc-2016-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm maximum…
/editions/2016-a1/ncc-2016-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm maximum…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-32-footings-and-slabs/part-323-concrete-and
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm…
/editions/2019/ncc-2019-volume-two/part-32-footings-and-slabs/part-323-concrete-and-reinforcing
3.2.3.1 Concrete
Concrete must comply with the following:
(a)
Concrete must be manufactured to comply with AS 3600; and—
(i)
have a strength at 28 days of not less than 20 MPa (denoted as N20 grade); and
(ii)
have a 20 mm…
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
/initiatives/use-performance
Find out how the Australian Building Codes Board is working to increase competent use of the National Construction Code's Performance Requirements.
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-2-abbreviations-and-symbols/schedule-2
Abbreviations and symbols used in the NCC include:
Abbreviations
Abbreviation
Definition
ABCB
Australian Building Codes Board
AC
Alternating Current
ACP
Aluminium Composite Panel
AS…