/editions/2016-a1/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2016/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2016-a1/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
/editions/2016/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
Schedule of Products - Devices and Controllers
/schedule-products-devices-and-controllers
Schedule of Products - Devices and Controllers
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/specification-f52
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of
construction.
(b)
Wall systems listed in…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry…
/editions/2016-a1/ncc-2016-volume-two/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative structural steel member system is proposed as a Performance Solution to that described in Part 3.4.4, that proposal must comply with—
P2.1.1;…
/editions/2016/ncc-2016-volume-two/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative structural steel member system is proposed as a Performance Solution to that described in Part 3.4.4, that proposal must comply with—
P2.1.1;…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative structural…
/editions/2019/ncc-2019-volume-two/part-34-framing/part-344-structural-steel-members
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative structural steel member system is proposed as a Performance Solution to that described in Part 3.4.4, that proposal must comply with…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jvc
1. Scope
This Specification contains modelling profiles as referenced in subclause 3(c)(vii) of Specification JVb.
Intent
To prescribe the operation profiles that may be used in the modelling required by JV2 and JV3.
2. Modelling…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jvc-modelling-profiles
1. Scope
This Specification contains modelling profiles as referenced in subclause 3(c)(vii) of Specification JVb.
Intent
To prescribe the operation profiles that may be used in the modelling required by JV2 and JV3.
2. Modelling…
/editions/2016-a1/ncc-2016-volume-two/part-38-health-and-amenity/part-386-sound-insulation
Appropriate Performance Requirements
Appropriate
Performance Requirements:
Where an alternative sound insulation system is proposed as a Performance Solution to that described in Part 3.8.6, that proposal must comply with—
P2.4.6; and…
/editions/2016/ncc-2016-volume-two/part-38-health-and-amenity/part-386-sound-insulation
Appropriate Performance Requirements
Appropriate
Performance Requirements:
Where an alternative sound insulation system is proposed as a Performance Solution to that described in Part 3.8.6, that proposal must comply with—
P2.4.6; and…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-38-health-and-amenity/part-386-sound
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative sound…
/editions/2019/ncc-2019-volume-two/part-38-health-and-amenity/part-386-sound-insulation
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative sound insulation system is proposed as a Performance Solution to that described in Part 3.8.6, that proposal must comply with—…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/specification-jv-annual-energy
1. Scope
This Specification contains the requirements for calculating the annual energy consumption of services in a building.
Intent
To clarify the requirements of the calculation for the annual energy consumption of services.
2.…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/specification-jv-annual-energy
1. Scope
This Specification contains the requirements for calculating the annual energy consumption of services in a building.
Intent
To clarify the requirements of the calculation for the annual energy consumption of services.
2.…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/northern-territory/section-f-health-and-amenity
Part F5 Sound transmission and insulation
NT FP5.1 Sound transmission through floors
Floors separating sole-occupancy
units must provide insulation against the transmission of airborne and impact…