/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-4-referenced-documents/schedule-4
Schedule of referenced documents
The Standards and other documents listed in Schedule 4 are referred to in the NCC.
Table 1 Schedule of referenced documents
No.
Date
Title
Volume One
Volume Two…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-4-referenced-documents/schedule-4
Schedule of referenced documents
The Standards and other documents listed in Schedule 4 are referred to in the NCC.
Table 1 Schedule of referenced documents
No.
Date
Title
Volume One
Volume Two…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-4-list-reference-documents/schedule-4
Schedule of referenced documents
The Standards and other documents listed in Schedule 4 are referred to in the NCC.
Table 1 Schedule of referenced documents
No.
Date
Title
Volume One
Volume Two…
/ncc-navigator/thermal-bridging-commercial-buildings
This NCC Navigator provides an introduction to thermal bridging and how the NCC addresses it for commercial buildings in NCC Volume One. It explains how to account for thermal bridges when calculating the Total R-Value of certain construction types.…
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e31
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2016/ncc-2016-volume-one/section-d-access-and-egress/part-d3-access-people-disability
D3.0 Deemed-to-Satisfy Provisions
Tas D3.0
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.16, D2.1 to D2.25 and D3.1 to D3.12; and…
/editions/2016-a1/ncc-2016-volume-one/section-d-access-and-egress/part-d3-access-people-disability
D3.0 Deemed-to-Satisfy Provisions
Tas D3.0
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.16, D2.1 to D2.25 and D3.1 to D3.12; and…
/editions/2019/ncc-2019-volume-one/history-adoption/history-adoption
1.0 Adoption of BCA96
The 1996 edition of the BCA was adopted as set out in Table Amdt 1.0.
Table 1.0 History of adoption of BCA96
Administration
Adoption Date
Australian Government
1 July 1997
Australian Capital Territory
1 July…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/history-adoption/history-adoption
1.0 Adoption of BCA96
The 1996 edition of the BCA was adopted as set out in Table Amdt 1.0.
Table 1.0 History of adoption of BCA96…
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
/resource/calculator/ncc-2022-volume-two-gutters-downpipes-and-overflow-gdo-calculator
Assists in developing a better understanding of the NCC Volume Two ABCB Housing Provision Standard Gutters and Downpipes provisions.
To use the GDO Calculator enter information about the location, roof design and types of overflow measures. Based…
Schedule of Products - Pipes – Plastic
/schedule-products-pipes-plastic
Schedule of Products - Pipes – Plastic
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-d-access-and-egress/part-d3-access-people
D3.0 Deemed-to-Satisfy Provisions
Tas D3.0
(a)
Where a Deemed-to-Satisfy
Solution is proposed, Performance
RequirementsDP1 to DP6…
/editions/2019/ncc-2019-volume-one/section-d-access-and-egress/part-d3-access-people-disability
D3.0 Deemed-to-Satisfy Provisions
Tas D3.0
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.16, D2.1 to D2.25 and D3.1 to D3.12…
Temporary structures
/resource/standard/temporary-structures
This Standard provides technical design criteria requirements for temporary structures, covering structural safety (particularly determining appropriate wind actions), fire safety (including fire resistance of materials; fire safety services and…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-j15a-calculation-u
1. Scope
This specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction.
Intent
This Specification describes the two calculation methods for determining if wall-glazing construction complies…