/editions/2019/ncc-2019-volume-one/western-australia/section-h-special-use-buildings
Insert WA Part H101 as follows:
/editions/2019-a1/ncc-2019-volume-one-amendment-1/western-australia/section-h-special-use-buildings
Insert WA Part H101 as follows:
/editions/2019/ncc-2019-volume-two/part-38-health-and-amenity/part-387-condensation-management
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative condensation management system is proposed as a Performance Solution to that described in Part 3.8.7, that proposal must comply with—…
/news/2021/introducing-your-abcb-industry-board-members
The Australian Building Codes Board is made up of eighteen members including a Chair, the head of each state and territory building administration, a Commonwealth building policy representative, up to seven industry representatives, and a…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/ncc-navigator/thermal-bridging-commercial-buildings
This NCC Navigator provides an introduction to thermal bridging and how the NCC addresses it for commercial buildings in NCC Volume One. It explains how to account for thermal bridges when calculating the Total R-Value of certain construction types.…
/resource/case-study/calculating-total-r-value-case-study-2
This case study shows how to calculate the Total R-Value, including thermal bridging, for a wall system in a Class 6 shop located in climate zone 3. The wall component consists of solid concrete on a steel framed wall.
The Board
/about/board
The Australian Building Codes Board is a standards writing body responsible for the National Construction Code, the WaterMark Certification Scheme and the CodeMark Certification Scheme.
/resource/case-study/calculating-total-r-value-case-study-1
This case study shows how to calculate the Total R-Value, including thermal bridging, for a wall system in a Class 3 residential building located in climate zone 5. The wall component consists of fibre cement cladding on a timber framed wall.
/editions/2016/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/editions/2016-a1/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/ncc-navigator/thermal-bridging-residential-buildings
This document explains the requirements for reducing thermal bridging in residential buildings focusing on metal-framed walls, roofs, ceilings and floors. It provides practical guidance on compliance options and methods to improve energy efficiency and…
Schedule of Products - Shafts and pumping stations
/schedule-products-shafts-and-pumping-stations
Schedule of Products - Shafts and pumping stations
/news/2020/demonstrating-ncc-compliance-using-5113
AS 5113:2016 Classification of external walls of buildings based on reaction to fire performance (AS 5113) is a standard that sets out procedures and criteria for classifying external walls of buildings.