/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/211-design-scenario-rc
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/211-design-scenario-rc
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/211-design-scenario
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2016/ncc-2016-volume-two/part-37-fire-safety/part-375-alpine-areas
Performance Requirements
Appropriate Performance Requirements
Where an alternative alpine area egress design is proposed as a Performance Solution to that described in Part 3.7.5, that proposal must comply with—
; and
the relevant…
/editions/2016-a1/ncc-2016-volume-two/part-37-fire-safety/part-375-alpine-areas
Performance Requirements
Appropriate Performance Requirements
Where an alternative alpine area egress design is proposed as a Performance Solution to that described in Part 3.7.5, that proposal must comply with—
; and
the relevant…
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e31
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e31-lift
1. Scope
This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.
2. Lift cars exposed to solar radiation
(a)
A lift car exposed to solar radiation directly, or…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
Energy Efficiency NCC Volume Two
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1…
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3124-air-movement
3.12.4 Application
This Part applies to a habitable room in a Class 1 building.
3.12.4.1 Air movement
(a)
Air movement must be provided to habitable rooms in accordance with Table 3.12.4.1.
(b)
Air movement required by (a) may be…
/news/2019/big-changes-afoot
Simon Croft from the Housing Industry Association (HIA) outlines what the NCC 2019 changes mean for the residential sector and what all building professionals will need to know.
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jvb-modelling
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jvb
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/resource/report/accessible-housing-estimated-cost-impact-proposed-changes-ncc
This updated report presents an order of cost estimate for the proposed changes to the National Construction Code of Australia (NCC) to include mandatory minimum accessible housing provisions for new Class 1a (single residential) and Class 2 (…