/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-310-ancillary-provisions-and-additional/p3.10.3
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative design is proposed as a Performance Solution to that described in Part 3.10.3, that proposal must comply with—
Performance RequirementP2.1.2; and…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-310-ancillary-provisions-and-additional/p3.10.4
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where an alternative alpine area egress design is proposed as a Performance Solution to that described in Part 3.10.4, that proposal must comply with—…
/resource/handbook/construction-buildings-flood-hazard-areas-handbook
Provides an understanding of the provisions in the ABCB Standard for Construction of Buildings in Flood Hazard Areas. Offers additional advisory information outside the scope of the Standard. This handbook should be read in conjunction with the ABCB…
Handbook-flood-2012.pdf
(5.6 MB)
/editions/ncc-2022/adopted/volume-one/5-new-south-wales/g5-construction-bushfire-prone-areas
NSW G5P1 Bushfire resistance2019: NSW GP5.1
Delete clause G5P1 and insert NSW G5P1 as follows:
A building that…
/editions/ncc-2022/adopted/volume-one/7-queensland/g5-construction-bushfire-prone-areas
QLD G5P1 Bushfire resistance2019: QLD GP5.1
Delete clause G5P1 and insert QLD G5P1 as follows:
A building that…
/editions/ncc-2022/adopted/volume-one/8-south-australia/f2-wet-areas-and-overflow-protection
SA F2P1 Wet area overflows2019: SA FP1.6
Delete clause F2P1 and insert SA F2P1 as follows:
Overflow from a…
/editions/ncc-2022/adopted/volume-one/8-south-australia/g5-construction-bushfire-prone-areas
SA G5D1 Deemed-to-Satisfy Provisions2019: G5.0
Delete subclause G5D1(1) and insert SA G5D1(1) as follows:
(1)…
/editions/ncc-2022/adopted/volume-one/9-tasmania/g5-construction-bushfire-prone-areas
TAS G5P1 Bushfire resistance2019: GP5.1
Delete clause G5P1 and insert TAS G5P1 as follows:
A building that is…
/editions/ncc-2022/adopted/volume-one/10-victoria/g5-construction-bushfire-prone-areas
VIC G5O1 Objective2019: GO5
Delete clause G5O1 and insert VIC G5O1 as follows:
The Objective of this Part is to…
/editions/2016-a1/ncc-2016-volume-two/part-38-health-and-amenity/part-381-wet-areas-and-external
Performance Requirements
Appropriate Performance Requirements:
Where an alternative system for external waterproofing a roof or external wall of a building is proposed as a Performance Solution to that described in Part 3.8.1, that proposal…
/editions/2016-a1/ncc-2016-volume-two/part-310-additional-construction-requirements/part-3101-high
Performance Requirements
Appropriate Performance Requirements:
Where an alternative method of constructing in high wind areas is proposed as a Performance Solution to that described in Part 3.10.1, that proposal must comply with—
P2.1.1; and
the…
/editions/2016-a1/ncc-2016-volume-two/part-310-additional-construction-requirements/part-3103-flood
Appropriate Performance Requirements
Appropriate Performance Requirements:
Where an alternative design is proposed as a Performance Solution to that described in Part 3.10.3, that proposal must comply with—
; and
the relevant Performance…
/editions/2016/ncc-2016-volume-two/part-310-additional-construction-requirements/part-3101-high-wind
Performance Requirements
Appropriate Performance Requirements:
Where an alternative method of constructing in high wind areas is proposed as a Performance Solution to that described in Part 3.10.1, that proposal must comply with—
P2.1.1; and
the…
/editions/2016/ncc-2016-volume-two/part-310-additional-construction-requirements/part-3103-flood
Appropriate Performance Requirements
Appropriate Performance Requirements:
Where an alternative design is proposed as a Performance Solution to that described in Part 3.10.3, that proposal must comply with—
; and
the relevant Performance…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/part-g4-dts
Deemed-to-Satisfy Provisions
G4.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy
Solution is proposed, Performance
Requirements GP4.1 to
GP4.4 are satisfied…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/part-g5
Performance Requirements
NSW GP5.1
Qld GP5.1
Bushfire Verification Method
GP5.1 Bushfire resistance
A building that is constructed in a designated bushfire prone area must, to the degree necessary, be designed and constructed to…
/editions/2016/ncc-2016-volume-one/section-b-structure/specification-b12-design-buildings-cyclonic
1. Scope
This specification contains requirements for the design of buildings in cyclonic areas in addition to the requirements of AS/NZS 1170.2.
For the purposes of Specification B1.2, cyclonic areas are those determined as being located in wind…
/editions/2016/ncc-2016-volume-one/section-g-ancilliary-provisions/part-g4-construction-alpine-areas
GP4.1
An external doorway from a building in an alpine area must be installed so that opening the door is not obstructed by snow or ice.
Application
Application
applies to a building constructed in an alpine area overrules other provisions of…
/editions/2016/ncc-2016-volume-one/section-g-ancilliary-provisions/part-g4-construction-alpine-areas
G4.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with G4.1 to G4.9.
(b)
Where a Performance Solution is proposed, the relevant Performance…
/editions/2016/ncc-2016-volume-one/queensland/qld-part-g5-construction-bushfire-prone-areas
Delete GP5.1 and insert Qld GP5.1 as follows:
Qld GP5.1
A building that is constructed in a designated bushfire prone area must be designed and constructed to reduce the risk of ignition from a bushfire while the fire front passes.…