Schedule of Products - Fittings – Metallic
/schedule-products-fittings-metallic
Schedule of Products - Fittings – Metallic
/editions/2016/ncc-2016-volume-one/section-b-structure/part-b1-structural-provisions-performance
PERFORMANCE REQUIREMENTS
BP1.1
(a)
A building or structure, during construction and use, with appropriate degrees of reliability, must—
(i)
perform adequately under all reasonably expected design actions; and
(ii)
withstand extreme or…
/editions/2016-a1/ncc-2016-volume-one/section-b-structure/part-b1-structural-provisions-performance
PERFORMANCE REQUIREMENTS
BP1.1
(a)
A building or structure, during construction and use, with appropriate degrees of reliability, must—
(i)
perform adequately under all reasonably expected design actions; and
(ii)
withstand extreme or…
/editions/2019/ncc-2019-volume-one/section-b-structure/part-b1-structural-provisions
Performance Requirements
BP1.1 Structural Reliability
(a)
A building or structure, during construction and use, with appropriate degrees of reliability, must—
(i)
perform adequately under all reasonably expected design actions; and…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-b-structure/part-b1-structural-provisions
Performance Requirements
BP1.1 Structural Reliability
(a)
A building or structure, during construction and use, with appropriate degrees of reliability, must—
(i)
perform adequately under all reasonably expected design actions; and…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3121-building
3.12.1 Application
(a)
The provisions of 3.12.1.1 to
3.12.1.5 apply to—
(i)
a Class 1 building; and…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3121-building-fabric
3.12.1 Application
(a)
The provisions of 3.12.1.1 to 3.12.1.5 apply to—
(i)
a Class 1 building; and
(ii)
a Class 10a building with a conditioned space.
(b)
The provisions of 3.12.1.6 apply to a Class 1 building with…
/editions/2016/ncc-2016-volume-two/section-1-general-requirements/part-10-application
1.0.1 Compliance with the NCC
Compliance with the NCC is achieved by satisfying the Performance Requirements.
1.0.2 Meeting the Performance Requirements
The Performance Requirements can only be satisfied by a—
(a)
Performance Solution; or…
/editions/2016-a1/ncc-2016-volume-two/section-1-general-requirements/part-10-application
1.0.1 Compliance with the NCC
Compliance with the NCC is achieved by satisfying the Performance Requirements.
1.0.2 Meeting the Performance Requirements
The Performance Requirements can only be satisfied by a—
(a)
Performance Solution; or…
Stochastic model CO toxicity building fires
/resource/report/stochastic-model-co-toxicity-building-fires
Fire Code Reform Centre (Project 4) This Technical Report, A Stochastic Model for CO Toxicity in Building Fires, involves the development of a Fundamental Model, incorporating engineering, risk-assessment methodology and the study of human behaviour in…
Selected literature reviews human behaviour fire
/resource/report/selected-literature-reviews-human-behaviour-fire
Fire Code Reform Centre (Project 4) This Technical Report, Selected Literature Reviews on Human Behaviour in Fire, involved the development of a Fundamental Model, incorporating engineering, risk-assessment methodology and the study of human behaviour…
The effects of sleep inertia on decision making performance
/resource/report/effects-sleep-inertia-decision-making-performance
Fire Code Reform Centre (Project 4) This Technical Report, The Effects of Sleep Inertia on Decision-Making Performance, involved with the development of a Fundamental Model, incorporating engineering, risk-assessment methodology and the study of human…
The probability of death in the room of fire origin an engineering formula
/resource/report/probability-death-room-fire-origin-engineering-formula
Fire Code Reform Centre (Project 4) This Technical Report, The Probability of Death in the Room of Fire Origin: an Engineering Formula, involved the development of a Fundamental Model, incorporating engineering, risk-assessment methodology and the…
Arousal from sleep smoke detector in children and adults
/resource/report/arousal-sleep-smoke-detector-children-and-adults
Fire Code Reform Centre (Project 4) This Technical Report, Arousal from Sleep with a Smoke Detector in Children and Adults, involved the development of a Fundamental Model, incorporating engineering, risk-assessment methodology and the study of human…
/news/2017/non-compliant-and-non-conforming-products
Much has been said about the cladding used at Grenfell Tower not complying with the standards in the United Kingdom.
/editions/2016/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2016-a1/ncc-2016-volume-two/section-1-general-requirements/part-14-documents-adopted
1.4.1 Schedule of referenced documents
The documents listed in Table 1.4.1 are referred to in the Housing Provisions.
Table 1.4.1: SCHEDULE OF REFERENCED DOCUMENTS
No
Date
Title
BCA Clause(s)
AS/NZS 1170
Structural design actions…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/12-how
This Verification Method sets out twelve design scenarios that must be considered in order to demonstrate that a building incorporating one or more Performance Solutions satisfies the Performance Requirements set out in Table 1.1.
Each design…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/12-how
This Verification Method sets out twelve design scenarios that must be considered in order to demonstrate that a building incorporating one or more Performance Solutions satisfies the Performance Requirements set out in Table 1.1.
Each design…
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/12-how-use
This Verification Method sets out twelve design scenarios that must be considered in order to demonstrate that a building incorporating one or more Performance Solutions satisfies the Performance Requirements set out in Table 1.1.
Each design…