/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jvb-modelling
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jvb
ACT Appendix
1. Scope
This Specification contains the required modelling parameters for JV2 and JV3.
Intent
To prescribe how the modelling of the proposed and reference building is to be carried out under JV2 and JV3.
This…
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/specification-j15-wall-construction
1. Scope
This Specification describes the thermal performance of some common forms of external wall construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of wall construction.
2.…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/specification-j15-wall
1. Scope
This Specification describes the thermal performance of some common forms of external wall construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of wall construction.
2.…
/pcd/pcd-2025-commercial-building-energy-efficiency
These changes aim to reduce emissions, providing cost-effective fuel and technology neutral ways for buildings to move to a net zero future.
NCC Floor Insulation - Final Report
/resource/report/ncc-floor-insulation-final-report
This report reviews Section J1.6 and Specification J1.6 of the 2016 and 2019 NCC to determine whether it is appropriate to set a different minimum total R-value requirement for floors of small buildings, provide advice on how Specification J1.6 should…
NCC Floor Insulation Final Report.pdf
(2.82 MB)
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3121-building-fabric
3.12.1 Application
(a)
The provisions of to 3.12.1.5 apply to—
(i)
a Class 1 building; and
(ii)
a Class 10a building with a conditioned space.
(b)
The provisions of 3.12.1.6 apply to a Class 1 building with an attached Class 10a…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3121-building-fabric
3.12.1 Application
(a)
The provisions of to 3.12.1.5 apply to—
(i)
a Class 1 building; and
(ii)
a Class 10a building with a conditioned space.
(b)
The provisions of 3.12.1.6 apply to a Class 1 building with an attached Class 10a…
Multi-storey carparks: Learning from overseas incidences
/news/2018/multi-storey-carparks-learning-overseas-incidences
Through the ABCB’s involvement in the Inter-Jurisdictional Regulatory Collaboration Committee, the ABCB has learnt of two incidents involving multi-storey carparks.
/editions/2016/ncc-2016-volume-one/section-j-energy-efficiency/specification-j13-roof-and-ceiling
1. Scope
This Specification describes the thermal performance of some common forms of roof and ceiling construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of roof and ceiling construction…
/editions/2016-a1/ncc-2016-volume-one/section-j-energy-efficiency/specification-j13-roof-and-ceiling
1. Scope
This Specification describes the thermal performance of some common forms of roof and ceiling construction.
Intent
To clarify that outlines the thermal performance of some of the more common forms of roof and ceiling construction…
November CEO update - Gary Rake
/news/2023/november-ceo-update-gary-rake
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-j15b-spandrel-panel
1. Scope
This Specification describes methods of determining the thermal performance of spandrel panels.
Intent
To detail how to calculate the thermal performance of spandrel panels.
2. Spandrel panel R-Value: Calculation method 1
Spandrel…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-j15b
1. Scope
This Specification describes methods of determining the thermal performance of spandrel panels.
Intent
To detail how to calculate the thermal performance of spandrel panels.
2. Spandrel panel R-…
/editions/2016/ncc-2016-volume-one/new-south-wales/section-h-special-use-buildings
Part H1 Class 9b Buildings
Delete H1.1 and insert NSW H1.1 as follows:
NSW H1.1 Application of Part
(a)
For a Class 9b building or part of a building that is not an entertainment venue—
(i)
The Deemed-to-Satisfy Provisions of Part H1…
/editions/2016-a1/ncc-2016-volume-one/new-south-wales/section-h-special-use-buildings
Part H1 Class 9b Buildings
Delete H1.1 and insert NSW H1.1 as follows:
NSW H1.1 Application of Part
(a)
For a Class 9b building or part of a building that is not an entertainment venue—
(i)
The Deemed-to-Satisfy Provisions of Part H1…
/editions/2019/ncc-2019-volume-one/new-south-wales/section-h-special-use-buildings
Part H1 Class 9b buildings
Delete H1.1 and insert NSW H1.1 as follows:
NSW H1.1 Application of Part
(a)
For a Class 9b building or part of a building that is not an entertainment venue—
(i)
The Deemed-to-Satisfy Provisions of Part H1…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/new-south-wales/section-h-special-use-buildings
Part H1 Class 9b buildings
Delete H1.1 and insert NSW H1.1 as follows:
NSW H1.1 Application of Part
(a)
For a Class 9b building or part of a building that is not an entertainment…
/editions/2016-a1/ncc-2016-volume-three/queensland/section-b-water-services
Part B1 Cold Water Services
Delete B1.2(a) and (c) and insert Qld B1.2(a) and (c) as follows:
Qld B1.2 General requirements
(a)
The design, construction, installation, replacement, repair, alteration and maintenance of cold water services…
/editions/2016/ncc-2016-volume-three/queensland/section-b-water-services
Part B1 Cold Water Services
Delete B1.2(a) and (c) and insert Qld B1.2(a) and (c) as follows:
Qld B1.2 General requirements
(a)
The design, construction, installation, replacement, repair, alteration and maintenance of cold water services…