/editions/2016/ncc-2016-volume-one/south-australia/section-c-fire-resistance
Part C1 Fire Resistance and Stability
After C1.1(a)(iv) add SA C1.1(a)(v), and after C1.1(b) add SA C1.1(c) and (d) as follows:
SA C1.1 Type of construction required
(a)
The minimum Type of fire-resisting construction of a building must be…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/specification-f52
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of
construction.
(b)
Wall systems listed in…
/editions/2016/ncc-2016-volume-two/part-38-health-and-amenity/part-386-sound-insulation
Appropriate Performance Requirements
Appropriate
Performance Requirements:
Where an alternative sound insulation system is proposed as a Performance Solution to that described in Part 3.8.6, that proposal must comply with—
P2.4.6; and…
/editions/2016-a1/ncc-2016-volume-two/part-38-health-and-amenity/part-386-sound-insulation
Appropriate Performance Requirements
Appropriate
Performance Requirements:
Where an alternative sound insulation system is proposed as a Performance Solution to that described in Part 3.8.6, that proposal must comply with—
P2.4.6; and…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e15
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that Specification E1.5 gives the design and installation details for sprinkler systems required by the Deemed-to-…
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e15-fire-sprinkler
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that Specification E1.5 gives the design and installation details for sprinkler systems required by the Deemed-to-…
/editions/2019/ncc-2019-volume-one/section-g-ancillary-provisions/part-g3-atrium-construction
G3.1 Application of Part
This Part does not apply to an atrium which—
(a)
connects only 2 storeys; or
(b)
connects only 3 storeys if—
(i)
each storey is provided with a sprinkler system (other than a FPAA101D or FPAA101H system…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/part-g3-atrium
G3.1 Application of Part
This Part does not apply to an atrium which—
(a)
connects only 2 storeys; or
(b)
connects only 3 storeys if—
(i)
each storey is provided with a sprinkler system (other than a FPAA101D or FPAA101H system…
/editions/2016-a1/ncc-2016-volume-two/new-south-wales/nsw-11-garage-top-dwellings-acceptable
Appropriate Performance Requirements
Appropriate
Where a Performance Solution to NSW 1.1 is proposed, that proposal must comply with—
(a)
; and
(b)
; and
(c)
relevant Performance Requirements determined in accordance with 1.0.7…
/editions/2016/ncc-2016-volume-two/new-south-wales/nsw-11-garage-top-dwellings-acceptable
Appropriate Performance Requirements
Appropriate
Where a Performance Solution to NSW 1.1 is proposed, that proposal must comply with—
(a)
; and
(b)
; and
(c)
relevant Performance Requirements determined in accordance with 1.0.7…
/editions/2019/ncc-2019-volume-two/new-south-wales/nsw-11-garage-top-dwellings-acceptable
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where a Performance Solution to NSW 1.1 is proposed, that proposal must comply with—
Performance RequirementP2.3.1; and
Performance RequirementP2.3.2;…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/new-south-wales/nsw-11-garage-top-dwellings
Appropriate Performance Requirements
Appropriate
Performance Requirements
Where a Performance Solution to NSW 1.1 is proposed, that proposal must comply with—
Performance RequirementP2.3.1; and
Performance RequirementP2.3.2;…
/editions/2019/ncc-2019-volume-one/section-g-ancillary-provisions/specification-g38-fire-and-smoke
1. Scope
This Specification sets out the requirements for the design and operation of systems of fire and smoke control in buildings containing an atrium.
Intent
To clarify that Specification G3.8 includes the requirements for fire and smoke control…
/editions/2016-a1/ncc-2016-volume-one/section-g-ancilliary-provisions/specification-g38-fire-and
1. Scope
This Specification sets out the requirements for the design and operation of systems of fire and smoke control in buildings containing an atrium.
Intent
To clarify that includes the requirements for fire and smoke control systems in…
/editions/2016/ncc-2016-volume-one/section-g-ancilliary-provisions/specification-g38-fire-and-smoke
1. Scope
This Specification sets out the requirements for the design and operation of systems of fire and smoke control in buildings containing an atrium.
Intent
To clarify that includes the requirements for fire and smoke control systems in…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-g-ancillary-provisions/specification-g38
1. Scope
This Specification sets out the requirements for the design and operation of systems of fire and smoke control in
buildings containing an atrium.
Intent
To clarify that…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/part-j5-air-conditioning-and
J5.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementJP1 is satisfied by complying with—
(i)
J0.1 to J0.5; and
(ii)
J1.1 to J1.6; and
(iii)
J3.1 to J3.7; and…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/part-j5-air
J5.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy
Solution is proposed, Performance
RequirementJP1 is
satisfied by complying with—
(i…
/editions/2019/ncc-2019-volume-one/tasmania/section-g-ancillary-provisions
Part G1 Minor structures and components
Tas GP1.2 Swimming pool access and water recirculation systems
(a)
A barrier must be provided to a swimming pool and must—
(i)
be continuous for the full extent of the hazard; and
(ii…