Skip to main content
  • ABCB
  • NCC Online
  • WaterMark
  • CodeMark

NCC 2022 online services are temporarily affected

We are working to fix some display issues with NCC 2022 online. You can still download each volume via the editions page. We apologise for any inconvenience. 

Home
  • Log in
  • Register
  • Reset password
Subscribe
  • Vol 1
  • Vol 2
  • Vol 3
  • NCC Editions
  • Propose a Change
  • Industry Practitioners
  • Resources
      1. Calculators
      2. Resource Library
      3. NCC CPD
      4. NCC Micromodules
      5. NCC Tutor
      6. NCC Tutor presentations for educators
      7. NCC Navigator
      8. Case Studies
  • Homeowners
      1. Common building features in homes
      2. Getting help with the National Construction Code
      3. How the NCC applies to your home
      4. What the NCC does and does not cover
  • Help & Support

Breadcrumb

  1. Home
  2. Search

Search results

Specification J1.5a Calculation of U-Value and solar admittance
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-j15a
1. Scope This specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction. Intent This Specification describes the two calculation…
Lighting refurbishment of an office building
/resource/case-study/lighting-refurbishment-office-building

This Case Study outlines developing a DTS Solution for the energy efficiency of an interior lighting refurbishment for an office building. It is based on the DTS Provisions in Section J, Part J6 Artificial lighting in NCC Volume One.

The…

Case-study-lighting-refurbishment-office-building.pdf (1.2 MB)
2.8 Design scenario (FI)
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/28-design-scenario-fi
Fire brigade intervention Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire brigade can undertake fire brigade intervention until completion of search and rescue…
2.8 Design scenario (FI)
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/28-design-scenario-fi
Fire brigade intervention Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire brigade can undertake fire brigade intervention until completion of search and rescue…
2.8 Design scenario (FI)
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/28-design-scenario
Fire brigade intervention Design scenario in brief Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire brigade can undertake fire brigade intervention until…
2.8 Design scenario (FI)
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/28
Fire brigade intervention Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire brigade can undertake fire brigade intervention until completion of…
2.8 Design scenario (FI)
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/28
Fire brigade intervention Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire brigade can undertake fire brigade intervention until completion of search and rescue…
2.8 Design scenario (FI)
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/28
Fire brigade intervention Design scenario in brief Design scenario in brief This design scenario allows for fire brigade intervention. Required outcome Demonstrate that the fire…
Part 2.4 Health and amenity
/editions/2019/ncc-2019-volume-two/section-2-performance-provisions/part-24-health-and-amenity
Explanatory information: Explanatory information: Objective O2.4.1 Wet areas The Objective is to safeguard the occupants from illness or injury and protect the building from damage caused by the accumulation of internal moisture…
Part 2.4 Health and amenity
/editions/2019-a1/ncc-2019-volume-two-amendment-1/section-2-performance-provisions/part-24-health
Explanatory information: Explanatory information: Objective O2.4.1 Wet areas The Objective is to safeguard the occupants from illness or injury and protect the…
Part 3.5.1 Sheet roofing
/editions/2019/ncc-2019-volume-two/part-35-roof-and-wall-cladding/part-351-sheet-roofing
Appropriate Performance Requirements Appropriate Performance Requirements Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with— Performance…
Part 3.5.1 Sheet roofing
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-35-roof-and-wall-cladding/part-351-sheet
Appropriate Performance Requirements Appropriate Performance Requirements Where an alternative roof cladding is proposed as a…
Part F2 Sanitary and other facilities (DtS)
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/part-f2-sanitary-and-other-dts
Deemed-to-Satisfy Provisions F2.0 Deemed-to-Satisfy Provisions Vic F2.0 (a) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements FP2.1 to FP2.6 are satisfied by complying with— (i) F2.1 to F2.9; and (…
Part F2 Sanitary and other facilities (DtS)
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/part-f2-sanitary-and-dts
Deemed-to-Satisfy Provisions F2.0 Deemed-to-Satisfy Provisions Vic F2.0 (a) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements FP2.1 to FP2.6 are satisfied by complying with— (i) F2.1 to F2.9; and (…
Section A General Provisions
/editions/2016/ncc-2016-volume-one/tasmania/section-general-provisions
Tas A1.1 Definitions Insert definition for centre-based care class 4 facilityas follows: Centre-based care class 4 facility is a facility as defined in Centre Based Care Class 4 Standards. Insert definition for centre-based care class 5…
Section A General Provisions
/editions/2016-a1/ncc-2016-volume-one/tasmania/section-general-provisions
Tas A1.1 Definitions Insert definition for centre-based care class 4 facilityas follows: Centre-based care class 4 facility is a facility as defined in Centre Based Care Class 4 Standards. Insert definition for centre-based care class 5…
SA Part G7 Access for Maintenance
/editions/2016/ncc-2016-volume-one/south-australia/sa-part-g7-access-maintenance
OBJECTIVE SA GO7 The Objectives of this Part are— (a) to safeguard people from injury while cleaning windows; and (b) to safeguard people from injury or illness resulting from the creation of hazardous spaces between buildings…
SA Part G7 Access for Maintenance
/editions/2016-a1/ncc-2016-volume-one/south-australia/sa-part-g7-access-maintenance
OBJECTIVE SA GO7 The Objectives of this Part are— (a) to safeguard people from injury while cleaning windows; and (b) to safeguard people from injury or illness resulting from the creation of hazardous spaces between buildings…
SA Part G7 Access for maintenance
/editions/2019/ncc-2019-volume-one/south-australia/sa-part-g7-access-maintenance
Objective SA GO7 The Objectives of this Part are— (a) to safeguard people from injury while cleaning windows; and (b) to safeguard people from injury or illness resulting from the creation of hazardous spaces between buildings.…
SA Part G7 Access for maintenance
/editions/2019-a1/ncc-2019-volume-one-amendment-1/south-australia/sa-part-g7-access-maintenance
Objective SA GO7 The Objectives of this Part are— (a) to safeguard people from injury while cleaning windows; and (b) to safeguard people from injury or illness resulting from the…

Pagination

  • First page « First
  • Previous page ‹ Previous
  • …
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Next page Next ›
  • Last page Last »

Areas of Interest

  • Performance (12)
  • Plumbing and drainage (9)
  • Building services (8)
  • Fire safety (8)
  • Energy efficiency (7)
  • Health and amenity (7)
  • Structural safety (5)
  • Water services (5)
  • Access and egress (4)
  • NCC compliance (3)
  • Product certification (3)
  • Governing Requirements (1)

Content type

  • Show all (692)
  • NCC Page (580)
  • Page (43)
  • Article (42)
  • Resource (10)
  • NCC Navigator Page (6)
  • Video (2)
  • Page (CPD) (1)
  • (-) PCD (8)

Domain

File type

Get the latest news and articles from the ABCB delivered straight to you. Subscribe to ABCB communications here

In the spirit of reconciliation the Australian Building Codes Board acknowledges the Traditional Custodians of country throughout Australia and their connections to land, sea and community. We pay our respect to their elders past and present and extend that respect to all Aboriginal and Torres Strait Islander peoples today.

Home

Info

  • Copyright
  • Privacy
  • Disclaimer
  • Accessibility
  • Help & Support

Find us on:

  • Facebook
  • LinkedIn
  • Youtube