/editions/2019/ncc-2019-volume-one/section-d-access-and-egress/part-d1-provision-escape
Deemed-to-Satisfy Provisions
D1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.17, D2.1 to D2.25 and D3.1…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-d-access-and-egress/part-d1-provision
Deemed-to-Satisfy Provisions
D1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.17, D2.1 to D2.25 and D3.1…
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e22a-smoke
1. Scope
This Specification describes the installation and operation of automatic smoke detection and alarm systems.
Intent
To state that Specification E2.2a relates to the installation and operation of automatic alarm systems.
Automatic…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e2.2a
1. Scope
This Specification describes the installation and operation of automatic smoke detection and alarm systems.
Intent
To state that Specification E2.2a relates to the installation and operation of automatic alarm systems.
Automatic…
/ncc-2022-residential-energy-efficiency-final-decision-ris
Building Ministers’ agreed to include new residential energy efficiency provisions in the 2022 edition of the National Construction Code (NCC).
/news/2022/overview-changes-energy-efficiency-and-condensation
Here are the key changes in residential energy efficiency for NCC 2022.
/ncc-navigator/building-classifications
This guide provides information about the grouping of buildings as they are referred to in the NCC.
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-j-energy-efficiency/specification-jva
ACT Appendix
1. Scope
This Specification contains requirements that must be complied with in addition to the modelling requirements of JV1, JV2 and JV3.
Intent
To clarify that there are additional requirements to the modelling…
/editions/2019/ncc-2019-volume-one/section-j-energy-efficiency/specification-jva-additional
ACT Appendix
1. Scope
This Specification contains requirements that must be complied with in addition to the modelling requirements of JV1, JV2 and JV3.
Intent
To clarify that there are additional requirements to the modelling…
/news/2022/livable-housing-provisions-ncc-2022
The 2022 edition of the National Construction Code (NCC 2022) contains new provisions that will improve the suitability of new Australian homes for people with mobility constraints.
Registration is open for the NCC 2022 Webinar Series
/news/2023/registration-open-ncc-2022-webinar-series
Register now for our free webinars, being held online
from 20 - 24 March 2023.
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/27
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the level of safety be at least…
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/27-design-scenario
Rapid fire spread involving internal surface linings
Design scenario in brief
Design scenario in brief
Interior surfaces are exposed to a growing fire that potentially endangers building occupants.
Required outcome
Demonstrate that the…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/part-f6-condensation
Performance Requirements
FP6.1 Condensation and water vapour management
In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated with water vapour and condensation must be managed to minimise their impact on…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/tasmania/tas-part-h117-premises-lead-processing
Tas H117.1 Application of Part
This Part is applicable to every building in which lead processes are used.
Premises for lead processing must—
(a)
provide for the safety and comfort of workers; and
(b)
be constructed in a manner that…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/part-f6-condensation-management
Performance Requirements
FP6.1 Condensation and water vapour management
In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated with water vapour and condensation must be managed to minimise their impact on…