/editions/2019/ncc-2019-volume-one/south-australia/section-d-access-and-egress
Vary D1.2(b) by adding SA D1.2(b)(iii) and (iv)as follows:
SA D1.2 Number of exits required
(b)
Class 2 to 8 buildings—In addition to any horizontal exit, not less than 2 exits must be provided from the following:
(iii)
a storage shed in a…
/news/2017/fire-safety-high-rise-buildings
A lot has been said and debated about the recent Grenfell Tower apartments’ fire in London. It is not intended to repeat or extend that here
/editions/2016/ncc-2016-volume-one/new-south-wales/nsw-part-h103-drive-theatres
NSW H103.1 Application of Part
This Part applies to drive-in theatres.
NSW H103.2 Speaker standards
Speaker standards must—
(a)
be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
(b)
be capable of…
/editions/2016-a1/ncc-2016-volume-one/new-south-wales/nsw-part-h103-drive-theatres
NSW H103.1 Application of Part
This Part applies to drive-in theatres.
NSW H103.2 Speaker standards
Speaker standards must—
(a)
be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
(b)
be capable of…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/new-south-wales/nsw-part-h103-drive-theatres
NSW H103.1 Application of Part
This Part applies to drive-in theatres.
NSW H103.2 Speaker standards
Speaker standards must—
(a)
be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
(b)
be capable of…
/editions/2019/ncc-2019-volume-one/new-south-wales/nsw-part-h103-drive-theatres
NSW H103.1 Application of Part
This Part applies to drive-in theatres.
NSW H103.2 Speaker standards
Speaker standards must—
(a)
be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
(b)
be capable of…
/news/2022/new-whole-home-energy-efficiency-whats-it-all-about
You may have heard there are new whole-of-home (WOH) energy efficiency requirements for residential buildings in NCC 2022. But what does this actually mean?
/resources/videos/applying-ncc-provision-a224-interactive-case-study
This case study of a residential apartment building is applied using the NCC provision A2.2(4). This four-step process demonstrates a sanitary drainage Performance Solution.
/ncc-navigator/thermal-bridging-residential-buildings
This document explains the requirements for reducing thermal bridging in residential buildings focusing on metal-framed walls, roofs, ceilings and floors. It provides practical guidance on compliance options and methods to improve energy efficiency and…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-three-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/schedule-7-fire-safety-verification-method/211
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019/ncc-2019-volume-one/schedule-7-fire-safety-verification-method/211-design-scenario-rc
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019/ncc-2019-volume-two/schedule-7-fire-safety-verification-method/211-design-scenario-rc
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019/ncc-2019-volume-three/schedule-7-fire-safety-verification-method/211-design-scenario
Robustness check
Design scenario in brief
The fire design will be checked to ensure that the failure of a critical part of the fire safety system will not result in the design not meeting the Performance Requirements.
Required outcome…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been deliberately left blank.
Note…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/editions/2016/ncc-2016-volume-two/part-37-fire-safety/part-375-alpine-areas
Performance Requirements
Appropriate Performance Requirements
Where an alternative alpine area egress design is proposed as a Performance Solution to that described in Part 3.7.5, that proposal must comply with—
; and
the relevant…