/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/specification-c11-fire
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/specification-c11-fire-resisting
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/specification-c11-fire-resisting
1. Scope
This Specification contains requirements for the fire-resisting construction of building elements.
Intent
To clarify that Specification C1.1 contains requirements for fire-resisting construction of building elements.
Note that…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/part-c2-compartmentation-and-separation
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.13, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/part-c2-compartmentation-and
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/part-312-energy-efficiency/part-3122-external
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
Energy Efficiency NCC Volume Two
3.12.2.1 External glazing
(a)
The aggregate conductance…
/editions/2019/ncc-2019-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
Energy Efficiency NCC Volume Two
3.12.2.1 External glazing
(a)
The aggregate conductance…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-additions
Application of Western Australia additions
This appendix contains additional provisions for application in Western Australia as follows:
Heated water systems
WA 1.1 * * * * *
This clause has been deliberately left blank.
Note…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/part-c2-compartmentation-and-separation
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17; and
(ii)
in a building…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/part-c2-compartmentation
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17; and
(ii)
in a building…
/editions/2016/ncc-2016-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
3.12.2.1 External glazing
(a)
The aggregate conductance of the glazing in each storey, including any…
/editions/2016-a1/ncc-2016-volume-two/part-312-energy-efficiency/part-3122-external-glazing
3.12.2 Application
This Part applies to—
(a)
a Class 1 building; and
(b)
a Class 10a building with a conditioned space.
3.12.2.1 External glazing
(a)
The aggregate conductance of the glazing in each storey, including any…
/editions/2019-a1/ncc-2019-volume-two-amendment-1/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/editions/2019/ncc-2019-volume-two/western-australia/western-australia-variations
Application of Western Australian variations
This Appendix contains variations for application in Western Australia as follows:
WA Schedule 3 Definitions
Insert definition for potable water as follows:
Potable water
means water…
/editions/2016/ncc-2016-volume-one/new-south-wales/section-c-fire-resistance
Part C1 Fire Resistance and Stability
Delete C1.10(a)(v), C1.10(b) and C1.10(c)(xiii) and insert NSW C1.10(a)(v), NSW C1.10(b) and NSW C1.10(c)(xiii) as follows:
NSW C1.10 Fire hazard properties
(a)
The fire hazard properties of the following…
/editions/2016-a1/ncc-2016-volume-one/new-south-wales/section-c-fire-resistance
Part C1 Fire Resistance and Stability
Delete C1.10(a)(v), C1.10(b) and C1.10(c)(xiii) and insert NSW C1.10(a)(v), NSW C1.10(b) and NSW C1.10(c)(xiii) as follows:
NSW C1.10 Fire hazard properties
(a)
The fire hazard properties of the following…
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsCP1 to CP9 are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14 and C3.1 to C3.17; and
(ii)
in a building…
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.13, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/part-c3-protection-openings
C3.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…