/editions/2019/ncc-2019-volume-one/section-d-access-and-egress/part-d1-provision-escape
Deemed-to-Satisfy Provisions
D1.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1 to D1.17, D2.1 to D2.25 and D3.1…
Schedule of Products - Valves – Backflow prevention
/schedule-products-valves-backflow-prevention
Schedule of Products - Valves – Backflow prevention
/resource/advisory-note/fire-performance-external-walls-and-cladding
At its meeting on 19 February 2016, the Building Ministers’ Forum agreed to the development and implementation of a range of measures to help address risks associated with high risk cladding products on high rise buildings. This included a National…
WaterMark Home
/watermark-home
The WaterMark Certification Scheme is a mandatory scheme for plumbing and drainage products of a certain type. Certification ensures products are fit for purpose and appropriately authorised for use in plumbing and drainage installations.
/editions/2016/ncc-2016-volume-one/section-g-ancilliary-provisions/part-g1-minor-structures-and
G1.0 Deemed-to-Satisfy Provisions
(a)
Performance RequirementGP1.1 must be complied with.
Explanatory information
There is no Deemed-to-Satisfy Provision for this Performance Requirement.
Tas G1.0(b)
(b)
Where a Deemed-to-…
/editions/2016-a1/ncc-2016-volume-one/section-g-ancilliary-provisions/part-g1-minor-structures-and
G1.0 Deemed-to-Satisfy Provisions
(a)
Performance RequirementGP1.1 must be complied with.
Explanatory information
There is no Deemed-to-Satisfy Provision for this Performance Requirement.
Tas G1.0(b)
(b)
Where a Deemed-to-…
/editions/2016/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
/editions/2016-a1/ncc-2016-volume-one/section-f-health-and-amenity/specification-f52-sound
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry, where…
/editions/2016/ncc-2016-volume-one/section-d-access-and-egress/part-d2-construction-exits
D2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1
to D1.16, D2.1 to D2.25 and D3.1 to D3.12; and
(ii)
in a…
/editions/2016-a1/ncc-2016-volume-one/section-d-access-and-egress/part-d2-construction-exits
D2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance RequirementsDP1 to DP6, DP8 and DP9 are satisfied by complying with—
(i)
D1.1
to D1.16, D2.1 to D2.25 and D3.1 to D3.12; and
(ii)
in a…
/editions/2016/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/editions/2016-a1/ncc-2016-volume-one/tasmania/section-h-special-use-buildings-h113-h124
Tas Part H113 Foundries
Tas H113.1 Application of Part
This Part is applicable to every building or premises in which foundry operations are undertaken.
Foundries must provide for the comfort and safety of workers on the premises.
Tas H113.2…
/editions/2019/ncc-2019-volume-one/south-australia/section-e-services-and-equipment
E1.3 is varied by adding SA E1.3(c), (d), (e) and (f) as follows:
SA E1.3 Fire hydrants
(c)
In a farm building, in lieu of providing a fire hydrant system in accordance with E1.3(b)(i), the building may be provided with—
(i)
a fire hydrant…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/south-australia/section-e-services-and-equipment
E1.3 is varied by adding SA E1.3(c), (d), (e) and (f) as follows:
SA E1.3 Fire hydrants
(c)
In a farm building, in
lieu of providing a fire hydrant system in accordance with E1.3(b)(i…
What is WaterMark?
/plumbers/what-watermark
The National Construction Code (NCC) requires any plumbing or drainage product of a type listed on the WaterMark Schedule of Products, to be WaterMark certified. It must be certified and installed by a licensed plumbing practitioner.
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e48
1. Scope
This Specification contains requirements for photoluminescent exit signs.
Intent
To clarify that provides the design and installation details for photoluminescent exit signs.
What is Photoluminescence?
Photoluminescence is the…
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e48
1. Scope
This Specification contains requirements for photoluminescent exit signs.
Intent
To clarify that provides the design and installation details for photoluminescent exit signs.
What is Photoluminescence?
Photoluminescence is the…
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry…
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/specification-f52
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of
construction.
(b)
Wall systems listed in…
/editions/2019/ncc-2019-volume-one/section-g-ancillary-provisions/part-g1-minor-structures-and-dts
G1.0 Deemed-to-Satisfy Provisions
(a)
Performance RequirementGP1.1 must be complied with.
Explanatory information
There is no Deemed-to-Satisfy Provisio n for this Performance Requirement.
Tas G1.0(b)
(b)
Where a…