F2.4 Accessible sanitary facilities

In a building Open link in same pagerequired to be Open link in same pageaccessible

Open link in same pageSA F2.4(a)

Open link in same pageSA F2.4(b)

(b)

Open link in same pageaccessible unisex showers must be provided in accordance with Open link in same pageTable F2.4(b); and

(c)

at each bank of toilets where there is one or more toilets in addition to an Open link in same pageaccessible unisex Open link in same pagesanitary compartment at that bank of toilets, a Open link in same pagesanitary compartment suitable for a person with an ambulant disability in accordance with AS 1428.1 must be provided for use by males and females; and

(d)

an Open link in same pageaccessible Open link in same pagesanitary compartment must contain a closet pan, washbasin, shelf or bench top and adequate means of disposal of sanitary products; and

(e)

the circulation spaces, fixtures and fittings of all Open link in same pageaccessible sanitary facilities provided in accordance with Open link in same pageTable F2.4(a) and Open link in same pageTable F2.4(b) must comply with the requirements of AS 1428.1; and

(f)

an Open link in same pageaccessible unisex sanitary facility must be located so that it can be entered without crossing an area reserved for one sex only; and

(g)

where two or more of each type of Open link in same pageaccessible unisex sanitary facility are provided, the number of left and right handed mirror image facilities must be provided as evenly as possible; and

(h)

where male sanitary facilities are provided at a separate location to female sanitary facilities, Open link in same pageaccessible unisex sanitary facilities are only Open link in same pagerequired at one of those locations; and

(i)

an Open link in same pageaccessible unisex Open link in same pagesanitary compartment or an Open link in same pageaccessible unisex shower need not be provided on a Open link in same pagestorey or level that is not Open link in same pagerequired by Open link in same pageD3.3(f) to be provided with a passenger lift or ramp complying with AS 1428.1.

Table F2.4(a) Accessible unisex sanitary compartments

Class of building

Minimum accessible unisex sanitary compartments to be provided

Class 1b

(a) Not less than 1; and

(b) where private Open link in same pageaccessible unisex Open link in same pagesanitary compartments are provided for every Open link in same pageaccessible bedroom, common Open link in same pageaccessible unisex Open link in same pagesanitary compartments need not be provided.

Class 2

Where Open link in same pagesanitary compartments are provided in common areas, not less than 1.

Class 3 and Class 9c

(a) In every Open link in same pageaccessible Open link in same pagesole-occupancy unit provided with Open link in same pagesanitary compartments within the Open link in same pageaccessible Open link in same pagesole-occupancy unit, not less than 1; and

(b) at each bank of Open link in same pagesanitary compartments containing male and female Open link in same pagesanitary compartments provided in common areas, not less than 1.

Class 5, 6, 7, 8 or 9 — except for within a Open link in same pageward area of a Class 9a Open link in same pagehealth-care building

Where Open link in same pageF2.3 requires closet pans—

(a) 1 on every Open link in same pagestorey containing Open link in same pagesanitary compartments; and

(b) where a Open link in same pagestorey has more than 1 bank of Open link in same pagesanitary compartments containing male and female Open link in same pagesanitary compartments, at not less than 50% of those banks.

Class 10a except—

At each bank of Open link in same pagesanitary compartments containing male and female Open link in same pagesanitary compartments, not less than 1.

(a) a Class 10a appurtenant to another Class of building; and

(b) a Open link in same pagesanitary compartment dedicated to a single caravan/camping site

Open link in same pageSA Table F2.4(a)(i)

Table F2.4(b) Accessible unisex showers

Class of building

Minimum accessible unisex showers to be provided

Class 1b

(a) Not less than 1; and

(b) where private Open link in same pageaccessible unisex showers are provided for every Open link in same pageaccessible bedroom, common Open link in same pageaccessible unisex showers need not be provided.

Class 2

Where showers are provided in common areas, not less than 1.

Class 3 and Class 9c

(a) In every Open link in same pageaccessible Open link in same pagesole-occupancy unit provided with showers within the Open link in same pageaccessible Open link in same pagesole-occupancy unit, not less than 1; and

(b) 1 for every 10 showers or part thereof provided in common areas.

Class 5, 6, 7, 8 or 9 — except for within a Open link in same pageward area of a Class 9a Open link in same pagehealth-care building

Where Open link in same pageF2.3 requires 1 or more showers, not less than 1 for every 10 showers or part thereof.

Class 10a except—

Where showers are provided, 1 for every 10 showers or part thereof.

(a) a Class 10a appurtenant to another Class of building; and

(b) a Open link in same pagesanitary compartment dedicated to a single caravan/camping site

Open link in same pageSA Table F2.4(b)(i)